This is an archived snapshot of W3C's public bugzilla bug tracker, decommissioned in April 2019. Please see the home page for more details.

Bug 3137 - Wrong serialization format for schema-import-27
Summary: Wrong serialization format for schema-import-27
Status: VERIFIED FIXED
Alias: None
Product: XML Query Test Suite
Classification: Unclassified
Component: XML Query Test Suite (show other bugs)
Version: 0.9.0
Hardware: PC Windows XP
: P2 normal
Target Milestone: ---
Assignee: Andrew Eisenberg
QA Contact:
URL:
Whiteboard:
Keywords:
Depends on:
Blocks:
 
Reported: 2006-04-21 15:20 UTC by Alberto Massari
Modified: 2006-06-14 18:40 UTC (History)
0 users

See Also:


Attachments

Description Alberto Massari 2006-04-21 15:20:25 UTC
schema-import-27 computes 

  ($input-context1//atomic:integer) + ($input-context1//atomic:integer)

that involves integer numbers; however, it expects 2.5357935086466E13 as result, as if they were of type xs:double.
The correct result should be 25357935086466
Comment 1 Alberto Massari 2006-04-21 15:23:06 UTC
Also applies to 

  schema-import-6
  schema-import-7
  schema-import-10
  schema-import-11
  schema-import-14
  schema-import-15
  schema-import-18
  schema-import-19
  schema-import-26

Comment 2 Carmelo Montanez 2006-04-24 15:16:42 UTC
Alberto:

These Queries were changed to reflect Michael Kay's suggestion on bug
2895 from 
http://www.w3.org/Bugs/Public/show_bug.cgi?id=2895

Your comment applies just as well.  Changed the queries to use correct
normalization for integer/decimals.  Please close the bug if in agreement.

Thanks,
Carmelo